One form instead of hunting for a pro who does heat pump tune-ups.
A heat pump in South Carolina works all year. It keeps you cool from April through October and it's the thing heating your house most winters since electric heat is what most homes here run on. That double duty is why a tune-up matters more for a heat pump than for a furnace that only runs part of the year.
A tune-up covers the outdoor unit and the indoor coil, the refrigerant charge, the electrical connections, the thermostat settings, and the reversing valve that switches the system between heating and cooling. A tech checks airflow and drainage too. Catching a weak part now, before the first hot week or the first cold snap, means the system isn't struggling to keep up when you need it most.
Finding someone to do this work is its own chore. You could spend an afternoon searching for heat pump contractors near you, calling a few, explaining the same thing about your system to each one, then waiting on quotes to compare before you even know who's available. Most people don't have time for that, especially when the unit outside is already making a noise it shouldn't.
Submit a request here and that search ends. You're matched with one licensed contractor local to South Carolina, someone who works on heat pumps all year in this climate and knows what tends to wear out first in a system that never really gets a break. You explain your situation once, to one person, not to a string of companies filling your phone with calls and competing quotes.
What that tune-up actually includes, and what it costs to have it done, is below.
A heat pump tune-up covers both sides of the machine, because it runs both sides of the year. The contractor checks the refrigerant charge, since a system low on refrigerant struggles to pull heat out of the air in January the same way it struggles to pull heat out of your house in July. They clean the outdoor coil, which collects pollen and grass clippings all summer and loses its grip on heat transfer once it's coated. They check the reversing valve, the part that switches the system between heating and cooling, since a valve that sticks can leave you with no heat on a cold morning. They look at the defrost cycle, test electrical connections, and check airflow across the indoor coil. Because the same unit carries your heat all winter and your cooling all summer, a problem caught in October saves you from finding out about it the hard way in January, and the same goes in reverse come spring.
A contractor working on your heat pump moves through it in a set order. Pressure gets checked on both the suction and liquid lines, because one reading by itself can look fine while the other tells you the charge is off. The system gets run through a defrost cycle so the reversing valve can be watched moving between heating and cooling, since a valve that sticks leaves ice on the outdoor coil and a cold house behind it. That outdoor coil gets cleaned, because pollen and cut grass pack into the fins here and block the airflow the coil needs to do its job. The compressor's amp draw gets measured against the number on its nameplate, since a motor drawing more current than it should is already on its way out. Inside, at the air handler, the contractor checks that your backup heat strips only kick in when the heat pump can't keep up on its own, and tightens any low voltage connections that could otherwise cut the system off at the thermostat without warning.
What actually happens during the visit
The contractor checks refrigerant charge by measuring both the suction and liquid line pressures, not just one reading, since either side alone can hide a problem.
Switching the unit into defrost mode shows whether the reversing valve moves cleanly, because a sticking valve leaves the outdoor coil frosted and the house cold.
The outdoor coil gets cleaned since South Carolina's pollen and grass clippings pack into the fins and cut how much heat the coil can shed or absorb.
Amp draw on the compressor gets measured against the nameplate rating, because a motor pulling more current than it should is wearing out early.
The contractor checks the auxiliary heat strips come on only when the heat pump itself can't keep up, since strips that fire too often run up your electric bill.
Low voltage connections at the air handler get tightened, because a loose wire there can shut down heating or cooling at the thermostat with no warning.
A licensed local pro takes the request for your heat pump tune-up.
It costs nothing to send, and you don't have to hire anyone.
1
The contractor shuts off power at the disconnect before opening the unit.
2
Outdoor coil fins get checked and rinsed clean of dirt and grass clippings.
3
The contractor attaches gauges to read suction and liquid line pressure.
4
The system switches into defrost mode to test the reversing valve.
Power costs 15.12 cents per kilowatt-hour statewide
At 15.12 cents a kilowatt-hour, every degree your heat pump has to make up costs you year round, not just in summer. A unit running on a dirty coil or a low charge pulls more power to do the same job, and you pay for that on both sides of the year.
EIA-861 2025 statewide residential average
Before you get your heat pump maintenanceAfter you get your heat pump maintenance
Why does the contractor check the reversing valve during a tune-up?
You already know a heat pump runs backward in winter compared to how it runs in summer. That switch happens inside the unit, not something you see or hear much of, so it's reasonable to wonder why a tune-up would single out one valve instead of just checking if the system blows warm or cool air like it's supposed to.
It's the part that decides whether you get heat or cold air
The reversing valve is what tells the refrigerant which way to flow. Switch it one way and the outdoor coil absorbs heat while the indoor coil releases it, warming your house. Switch it the other way and the two coils trade jobs, cooling your house. If that valve sticks halfway, or doesn't shift all the way, the system can run with mismatched airflow, or get stuck in one mode no matter what the thermostat asks for. That's a hard failure to catch by just feeling the vents. The contractor forces the switch during the tune-up and watches both coils respond, so a sticking valve shows up now instead of on the first cold morning you need heat.
A dew point tells you how heavy the air actually feels, and here it averages 69°F across June, July and August. At that level the air is thick enough that your heat pump isn't just cooling, it's working to wring the moisture out of it too. A coil that's dirty or low on refrigerant can't pull that moisture out as well, so the air inside stays sticky even when the thermostat says you've hit your temperature. That's often the first sign something's off, not a warmer house, but one that still feels damp.
Source: NOAA climate normals
NASA POWER T2MDEW county cells weighted by homes
A clean coil like this one moves heat the way it's supposed to, in both July heat and January cold.
A coil caked with dirt and grime like this one makes the unit work harder to do the same job, all year.
Does your heat pump seem to be working harder than it used to?
Maybe the air coming out of the vents feels less cold in July, or less warm in January, so the system runs longer to get the house to temperature. Maybe you've noticed the outdoor unit icing over and staying that way, or it cycles on and off more than it used to. You might hear it running at hours it never used to, or notice the room by the thermostat feels fine while other rooms don't. None of that fixes itself. A system working harder to do the same job pulls more power doing it, and left alone, the part causing the strain usually gets worse, not better.
Coil running clean
This is what a heat pump should look like year round. The cabinet is clear, the coil fins are open, and air moves through them the way they were designed to. A unit kept this way pulls heat out of winter air and humidity out of summer air without straining to do it.
Coil caked with dirt
Grass clippings, pollen and dirt build up on the fins over time and block airflow through the coil. The unit still runs, but it works harder for the same result, in July heat and January cold alike. Left this way, it pulls more power and puts more strain on the compressor.
A tune-up on your heat pump means checking what it does in both directions
The contractor goes through the refrigerant charge, the outdoor coil, the reversing valve and the electrical components, because your heat pump has to work in July and it has to work in January, on the same equipment. Nothing about that changes whether the reader lives near the coast or further inland. What changes is whether it gets done before the next heavy stretch of heat or cold asks something of the unit it can't deliver.
You could spend an evening searching for someone who actually works on heat pumps rather than furnaces alone, call around to see who answers, explain the same thing about your unit three or four times, then sit with a handful of quotes trying to tell them apart. Request the service here instead and it goes to one licensed contractor local to South Carolina, someone who services this equipment every season and knows what tends to fail first in a system that runs both sides of the year. No flood of calls to sort through, just the one.
One form, no calling around
The pro who reaches out is licensed in South Carolina.